English 8. SPECIFICATIONS
G85139-H1751-U529-D1 © Siemens plc 199
4/8/99
66
380 V - 480 V Three Phase MICROMASTER Vector Inverters with built-in Class A filter
Order No. (6SE32..)
15-8DB50 17-3DB50 21-0DC50 21-3DC50 21-5DC50
Inverter model MMV220/3F MMV300/3F MMV400/3F MMV550/3F MMV750/3F
Input voltage range 3 AC 380 V - 480 V +/-10%
Motor output rating
a
(kW/ hp)
2.2 / 3 3.0 / 4 4.0 / 5 5.5 / 7½ 7.5 / 10
Continuous output @ 400V
a
4.0 kVA 5.2 kVA 7.0 kVA 9.0 kVA 12.1 kVA
Output current (nom.) (A) 5.2 6.8 9.2 11.8 15.8
Output current (max. continuous) (A)* 5.9 7.7 10.2 13.2 17.0
Input current (max.) (A) 8.8 11.1 13.6 17.1 22.1
Recommended mains fuse(A) 16 20 25
Fuse order code 3NA3805 3NA3807 3NA3810
Recommended lead Input 1.5 mm
2
2.5 mm
2
4.0 mm
2
cross-section (min.)
Output 1.0 mm
2
1.5 mm
2
2.5 mm
2
Dimensions (mm) (w x h x d) 149 x 184 x 172 185 x 215 x 195
Weight (kg / lb) 2.4 / 5.3 4.8 / 10.5
Class B may be achieved by adding a Class B footprint filter to an unfiltered inverter
230 V Three Phase MIDIMASTER Vector Inverters
Order No. - IP21 / NEMA 1 (6SE32..)
Order No. - IP20 / NEMA 1 with integrated filter
Order No. - IP56 / NEMA 4/12 (6SE32..)
22-3CG40
22-3CG50
22-3CS45
23-1CG40
23-1CG50
23-1CS45
24-2CH40
24-2CH50
24-2CS45
25-4CH40
25-4CH50
25-4CS45
26-8CJ40
26-8CJ50
26-8CS45
27-5CJ40
27-5CJ50
27-5CS45
Inverter model MDV550/2 MDV750/2 MDV1100/2 MDV1500/2 MDV1850/2 MDV2200/2
Constant Torque (CT)
Variable Torque (VT)
CT VT CT VT CT VT CT VT CT VT CT VT
Input voltage range 3 AC 208V - 240 V +/-10%
Motor output rating
(kW/hp) 5.5/ 7.5 7.5/ 10 7.5/ 10 11/ 15 11/ 15 - 15/ 20 18.5/25 18.5/25 22/ 30 22/ 30 30/ 40
Continuous output (kVA) @230V 8.8 11.2 11.2 16.7 16.7 - 21.5 27.1 27.1 31.9 31.9 35.8
Output current (max. continuous) (A) 22 28 28 42 42 - 54 68 68 80 80 95
Input current (max.) (A) 32 45 61 75 87 100
Recommended mains fuse (A) 50 63 80 100
Fuse order code 3NA3820 3NA3822 3NA3824 3NA3830
Recommended lead Input (min.) 6 10 16 n/a 25 35
cross-section (mm
2
)
Output (min.) 4 6 10 n/a 16 25 35
Dimensions (mm) IP21 / NEMA 1 275 x 450 x 210 275 x 550 x 210 275 x 650 x 285
(w x h x d)
IP20 / NEMA 1 with
integrated filter
275 x 700 x210 275 x 800 x 210 275 x 920 x 285
IP56 / NEMA 4/12 360 x 675 x 351 360 x 775 x 422 360 x 875 x 483
Weight (kg) IP21 / NEMA 1 11.0 14.5 15.5 26.5 27.0 27.5
IP20 / NEMA 1 with
integrated filter
18 22 23 37 38 38
IP56 / NEMA 4/12 30.5 38.0 40.0 50.5 52.5 54.5
* Output current ratings are reduced by 10% when operating on mains supply voltages over 460V.