Device Management
3.2Configuring the Device
The serial console port implements RS232 DCE (Data Communication Equipment) on
a DB9 connector. The following is the pin-out for the port:
Figure3.1 Serial DB9 Console Port
Pin Name Description
1
a
Reserved (Do Not Connect)
2 TX Transmit Data
3 RX Receive Data
4
a
Reserved (Do Not Connect)
5 GND Signal Ground
6
a
Reserved (Do Not Connect)
7
b
Reserved (Do Not Connect)
8
b
Reserved (Do Not Connect)
9 Reserved (Do Not Connect)
a
Connected internally.
b
Connected internally.
Ethernet Ports
Connect any of the available Ethernet ports on the device to a management
switch and access the RUGGEDCOM RS910 console and Web interfaces via the
device's IP address. The factory default IP address for the RUGGEDCOM RS910 is
https://192.168.0.1.
For more information about available ports, refer to "Communication Ports (Page
21)".
3.2 Configuring the Device
Once the device is installed and connected to the network, it must be configured.
All configuration management is done via the RUGGEDCOM RS910 interface. For
more information about configuring the device, refer to the RUGGEDCOM ROS
Configuration Manual associated with the installed software release.