Communication Ports
4.3Serial Ports
State Description
Off No link detected
Specifications
For specifications on the available fiber optic Ethernet ports, refer to "Fiber Optic
Ethernet Port Specifications (Page 31)".
4.3 Serial Ports
The RUGGEDCOM RS910 supports DB9, RJ45 and ST (Straight Tip) fiber serial ports,
all of which can be run in RS232, RS485 or RS422 mode.
Note
On power-up, all serial ports default to RS485 mode. Each port can be individually
set to RS232, RS485 or RS422 mode through RUGGEDCOM RS910 . For more
information, refer to the RUGGEDCOM ROS Configuration Manual for the
RUGGEDCOM RS910.
All serial ports feature an LED that indicates the current state of the port.
State Description
Green Link activity detected
Off No link detected
For specifications on serial ports, refer to "Serial Port Specifications (Page 32)".
4.3.1 Serial RS232/RS485/RS422 DB9 Ports
The RUGGEDCOM RS910 can be equipped with serial RS232/RS485/RS422 DB9 ports.
Each port can be set individually through the RUGGEDCOM ROS operating system
to operate in RS232, RS485 or RS422 mode. For more information, refer to the
RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RS910.
24
RUGGEDCOM RS910
Installation Manual, 04/2021, C79000-G8976-1029-12

Other manuals for Siemens RUGGEDCOM RS910

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RS910 and is the answer not in the manual?

Siemens RUGGEDCOM RS910 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RS910
CategorySwitch
LanguageEnglish

Related product manuals