RUGGEDCOM RX1500
Installation Guide
Chapter 4
Technical Specifications
Gigabit Ethernet (1 Gbps) Optical Specifications 43
Section 4.5.3
Gigabit Ethernet (1 Gbps) Optical Specifications
NOTE
Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens sales associate when determining maximum segment
distances.
All optical power numbers are listed as dBm averages.
F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).
Fixed Gigabit Transceivers
Mode
Connector
Type
Cable
Type (μm)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.) (km)
Power
Budget
(dB)
MM LC 50/125 850 -9 -2.5 -20 0 0.5 11
SM SC 9/125 1310 -10 -3 -20 -3 10 10
SM LC 9/125 1310 -9.5 -3 -21 -3 10 11.5
SM SC 9/125 1310 -5 0 -20 -3 25 15
SM LC 9/125 1310 -7 -3 -24 -3 25 17
SFP Gigabit Transceivers
Mode
Connector
Type
Cable
Type (μm)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.) (km)
Power
Budget
(dB)
50/125 0.5
MM LC
62.5/125
850 -9 -2.5 -20 0
0.3
11
SM LC 9/125 1310 -9.5 -3 -19 -3 10 9.5
SM LC 9/125 1310 -7 -3 -23 -3 25 16
SM LC 9/125 1550 0 5 -23 -3 70 23

Table of Contents

Other manuals for Siemens RUGGEDCOM RX1500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM RX1500 and is the answer not in the manual?

Siemens RUGGEDCOM RX1500 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM RX1500
CategorySwitch
LanguageEnglish

Related product manuals