Certification
6.2EMC and Environmental Type Tests
Test Description Test Levels Severity
Levels
± 1 kV Line-to-Line
AC Power Ports ± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
Signal ports
DC Power Ports
AC Power Ports
IEC 61000-4-6 Induced
(Conducted) RFI
Earth ground ports
10 V 3
100 A/m, continuous
1000 A/m for 1 s
Note
a
IEC 61000-4-8 Magnetic Field Enclosure Ports
1000 A/m for 1 s 5
IEC 61000-4-11 Voltage Dips
and Interrupts
AC Power Ports 30% for 1 period
60% for 50 periods
Signal ports
DC Power Ports
IEC 61000-4-12 Damped Oscillatory
AC Power Ports
2.5 kV common, 1 kV
differential mode @1 MHz
3
Signal portsIEC 61000-4-16 Mains Frequency
Voltage
DC Power Ports
30 V Continuous
300 V for 1 s
4
IEC 61000-4-17 Ripple on DC
Power Supply
DC Power Ports 10% 3
IEC 61000-4-29 Voltage Dips
and Interrupts
DC Power Ports 30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
Signal ports 2 kV (Failsafe Relay output)
DC Power Ports 1.5 kV
Dielectric Strength
AC Power Ports 2 kV
Signal ports 5 kV (Failsafe Relay output)
DC Power Ports
IEC 60255-27
HV Impulse
AC Power Ports
5 kV
a
Siemens-specified severity levels.
EMC Immunity Type Tests for IEEE 1613
Note
The RUGGEDCOM RX1524 meets Class 2 requirements for an all-fiber
configuration and Class 1 requirements for copper ports. Class 1 allows for
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
Description Test Levels
Signal ports 5 kV (Failsafe Relay Output)
DC Power Ports
HV Impulse
AC Power Ports
5 kV
RUGGEDCOM RX1524
Installation Manual, 04/2021, C79000-G8976-1487-02
53