Application and functions
1.8 Requirements for use
CP 1542SP-1, CP 1542SP-1 IRC, CP 1543SP-1
Operating Instructions, 01/2017, C79000-G8976-C426-03
19
Security functions
Only CP 1543SP-1
VPN tunnel
A maximum of four VPN tunnels can be established for secure communication with other
Security modules.
Firewall rules
The maximum number of firewall rules in advanced firewall mode is limited to 256. The
firewall rules are divided up as follows:
Maximum 226 rules with individual addresses
Maximum 30 rules with address ranges or network addresses
(e.g. 140.90.120.1 - 140.90.120.20 or 140.90.120.0/16)
Maximum 128 rules with limitation of the transmission speed ("Bandwidth limitation")
1.8
Requirements for use
1.8.1
Hardware requirements
Bus adapter
To connect to the Ethernet network, the CP requires a BusAdapter. A BusAdapter does not
ship with the CP.
The CP supports the following BusAdapter:
BA 2xRJ45
BA 2xFC
BA 2xSCRJ
BA SCRJ/RJ45
BA SCRJ/FC
For more detailed information on the bus adapters, refer to the section BusAdapter
(Page 117) and the manual /2/ (Page 119).
CPUs and other components of the ET 200SP
The CP supports operation in stations that contain one of the following CPUs:
CPU 1510SP-1 PN
Article number: 6ES7510-1DJ01-0AB0
CPU 1510SP F-1 PN
Article number: 6ES7510-1SJ01-0AB0
CPU 1512SP-1 PN
Article number: 6ES7512-1DK01-0AB0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET ET 200SP and is the answer not in the manual?

Siemens SIMATIC NET ET 200SP Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET ET 200SP
CategoryNetwork Router
LanguageEnglish

Related product manuals