Technical speci󹪝cations
Design of the mounting bracket for four-point mounting
Dimensions (W x H x D) 43.6 x 43.6 x 18.3mm (1 height unit)
Plate thickness 1.5mm
Bending radii 1.5mm
Surface of the housing Stainless steel X6CR17
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C) 6GK5334-2TS00-3AR3 > 8.3 years
6GK5334-2TS00-4AR3 > 10.2 years
1)
Wiring rules
Note the wiring rules (Page59).
2)
Ambient temperature with SFP
The maximum ambient temperature during operation depends on the operating elevation
and the installed plug-in transceivers, see also the section "SFP plug-in transceiver (Page31)"
in the "Accessories" section.
3)
Restriction when operating with plug-in transceivers of this type
A maximum of two plug-in transceivers of this type may be used.
4)
Derating
The derating values depend on the maximum ambient temperatures during operation up to
2000 m.
5)
Degree of protection
The degree of protection was not examined in the context of UL certi󹪝cation.
6)
Degree of protection
The degree of protection was not examined in the context of FM certi󹪝cation.
Technical speci󹪝cations
9.1SCALANCE XR326-8 and SCALANCE XR326-8EEC
SCALANCE XR-300
Operating Instructions, 03/2023, C79000-G8976-C586-02 91

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE XR-300 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE XR-300 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE XR-300
CategorySwitch
LanguageEnglish

Related product manuals