Technical specications
Current consumption Rated voltage 3A
Eective power loss Rated voltage 72W
Cable cross-section Minimum 0.75 mm^2 (AWG 18)
Maximum 2.5 mm^2 (AWG 12)
Permitted ambient conditions
Ambient temperature
2)
Property Startup at -40°C
With LAN operation with RJ45 plug
Up to 2000 m above sea level
During operation in horizontal installation position:
-40 to +70°C
When operating with plug-in trans‐
ceivers of the types:
• [-] Standard version
• LD except SFP993-1LD
• SFP993-1LD up to max. 4 units
Up to 2000 m above sea level
During operation in horizontal installation position:
-40°C to +60°C
When operating with SFP Transceiv‐
ers of the type:
• SFP993-1LD as of 5 units
Up to 2000 m above sea level
During operation in horizontal installation position:
-40°C to +55°C
When operating with plug-in trans‐
ceivers of the types
3)
:
• SFP992-1+
• LD+
• LH
• LH+
• ELH
• ELH200
• BXMR
• BXMT
• BX10T
• BX10R
Up to 2000 m above sea level
During operation in horizontal installation position:
-40 to +50°C
With operation between 2000m
and 3000m above sea level
The maximum ambient temperature is reduced by
5°C
4)
With operation between 3000m
and 4000m above sea level
The maximum ambient temperature is reduced by
10°C
4)
During storage -40°C to +85°C
During transportation -40°C to +85°C
Relative humidity During operation at 25 ℃ ≤ 95% without condensation
Housing, dimensions and weight
Design Rack
Housing material Metal
Degree of protection IP20
5) 6)
Technical specications
9.2SCALANCE XR322-12
SCALANCE XR-300
Operating Instructions, 03/2023, C79000-G8976-C586-02 93