Technical specications
Permitted ambient conditions
Ambient temperature
2)
Property Startup at -25°C
With LAN operation with RJ45 plug
Up to 2000 m above sea level
During operation in horizontal installation position:
-25°C to +60°C
When operating with plug-in trans‐
ceivers of the types:
• [-] Standard version
• LD except SFP993-1LD
• SFP993-1LD up to max. 4 units
Up to 2000 m above sea level
During operation in horizontal installation position:
-25°C to +60°C
When operating with SFP Transceiv‐
ers of the type:
• SFP993-1LD as of 5 units
Up to 2000 m above sea level
During operation in horizontal installation position:
-25 °C to +55°C
When operating with plug-in trans‐
ceivers of the types
3)
:
• SFP992-1+
• LD+
• LH
• LH+
• ELH
• ELH200
• BXMR
• BXMT
• BX10T
• BX10R
Up to 2000 m above sea level
During operation in horizontal installation position:
-25°C to +50°C
With operation between 2000m
and 3000m above sea level
The maximum ambient temperature is reduced by
5°C
4)
During storage -40°C to +85°C
During transportation -40°C to +85°C
Relative humidity During operation at 25 ℃ ≤ 95% without condensation
Housing, dimensions and weight
Design Rack
Housing material Metal
Degree of protection IP20
5) 6)
Dimensions (W x H x D) 446 x 43.5 x 384.8mm (1 height unit)
Weight Device version with one power sup‐
ply unit
8200 g
Device version with two power sup‐
ply units
8400g
Installation options
• 19" rack mounting
• Four-point mounting
Technical specications
9.2SCALANCE XR322-12
SCALANCE XR-300
96 Operating Instructions, 03/2023, C79000-G8976-C586-02