Note
The number of devices connected in a line, which are named in the scope of validity, in󹪞uences
the frame delay. When a frame passes through an IE switch, it is delayed by the store-and-
forward function of the device:
With a 64-byte frame length by about 10 microseconds (at 100 Mbps)
With a 1500-byte frame length by about 130 microseconds (at 100 Mbps)
This means that the more devices the frame passes through, the higher the frame run time.
Technical speci󹪝cations
9.5Switching properties
SCALANCE XR-300
Operating Instructions, 03/2023, C79000-G8976-C586-02 99