Pin Designation
1)
Signal type
2)
Notes
7 DI/DO 8 B Digital input/digital output 8
8 DI/DO 9 B Digital input/digital output 9 (can be used as a high-speed
input of the measuring input)
9 G GND Ground
10 DI/DO 10 B Digital input/digital output 10 (can be used as a high-speed
input of the measuring input)
11 DI/DO 11 B Digital input/digital output 11 (can be used as a high-speed
input of the measuring input)
12 G GND Ground
1)
DI: digital input; DI/DO: bidirectional digital input/output; G or GND: Electronics ground;
G1: Ground reference
2)
B = Bidirectional; I = Input; GND = Reference potential (ground)
Note
An open input is interpreted as "Low".
Terminal G1 must be connected for the digital inputs to function. The following alternatives
are available:
Connect the carried digital input reference ground to M1.
Create the bridge between terminal G and terminal G1.
This removes the electrical isolation for these digital inputs.
Using the digital inputs/outputs
Connecting sensors and actuators
Digital inputs and digital outputs can be used to connect various sensors and actuators to the
12-pin X122 front connector.
The following types of digital inputs/outputs are used:
Digital inputs
Bidirectional digital inputs/outputs
Bidirectional digital inputs and outputs can be configured individually as digital inputs or outputs.
Assignment of the inputs/outputs to functions can be parameterized as required. Special
functions (e.g. input of the measuring input) can be assigned to the inputs/outputs.
The enables for the drive units and/or motors (Active Line Module, Motor Module) connected
to the Control Unit can, for example, be switched using the digital inputs.
Digital inputs
There are 4 digital inputs on the CX32.
The electrically isolated inputs can be used as freely addressable inputs.
Bidirectional digital inputs/outputs
4 digital inputs/outputs (DI/DO) are available on the CX32.
When the DI/DO are assigned as digital inputs, they can be used as follows:
Supplementary system components
7.4 Controller Extension CX32
SIMOTION D4x5
100 Manual, 04/2014

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D4x5 Series and is the answer not in the manual?

Siemens SIMOTION D4x5 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D4x5 Series
CategoryControl Unit
LanguageEnglish

Related product manuals