Features Type
Flexible, with wire-end ferrule without plastic
sleeve
0.2 mm² … 2.5 mm²
Flexible, with wire-end ferrule with plastic
sleeve
0.2 mm² … 1.5 mm²
AWG / kcmil 22 … 12
Stripped length 6 … 7 mm
Tool Screwdriver 0.5 x 3 mm (M2.5)
Tightening torque 0.4 to 0.5 Nm
Max. current carrying capacity, incl. loop-through 20 A (15 A per UL/CSA)
Max. cable length 10 m
Interface assignments
Table 7-18 Power supply X124
Pin Signal name Signal type Meaning
1 + VI Power supply 24 V
2 + VI Power supply 24 V
3 G VO Ground
4 G VO Ground
Signal type: VI = Voltage input (power supply) VO = Voltage output (power supply)
Note
The 24 V supply voltage is looped through via the 24 V connector. In this case, pin 1 is
jumpered with pin 2, and pin 3 is jumpered with pin 4.
7.4.2.5
Measuring sockets
Application
The T0, T1 and T2 measuring sockets are used to output analog signals. Any interconnectable
signal can be output on any measuring socket of the CX32.
Note
The measuring sockets should be used exclusively for servicing purposes.
The measurements may only be performed by appropriately trained specialists.
The
measuring sockets are suited for multiple-spring wire connectors with a diameter of 2 mm.
Supplementary system components
7.4 Controller Extension CX32
SIMOTION D4x5
102 Manual, 04/2014

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D4x5 Series and is the answer not in the manual?

Siemens SIMOTION D4x5 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D4x5 Series
CategoryControl Unit
LanguageEnglish

Related product manuals