Meaning of the LED displays
This table describes the LEDs and their meaning.
Table 3-4
Error and status displays
LED Meaning
RDY ... indicates the operating states of SIMOTION D incl. SINAMICS Integrated.
RUN ... indicates that the user program is running.
STOP ... indicates that a user program is not running. The technology packages are not active.
SU/PF ... indicates that the technology packages are active. The user program is not active.
SF ... indicates an error state of the SIMOTION D4x5.
DP1 ... indicates the state of the PROFIBUS DP1 interface.
DP2 ... indicates the state of the PROFIBUS DP2/MPI interface.
OPT ... indicates the state of the option module (if available).
Note
While the SIMOTION D4x5 is ramping up, all LEDs are briefly illuminated in yellow.
7-segment display
The 7-segment display provides further status information in addition to the LED displays.
The
status "6" and a flashing "." indicate that the D4x5 has ramped up and communication has
been established to the SINAMICS Integrated.
Additional information
You can carry out a detailed diagnosis using a PG/PC and the Engineering System. Information
on the diagnosis via LED displays can also be found in the Commissioning and Hardware
Installation Manual
SIMOTION D4x5
and in the Online Help of this chapter via the link under
menu instructions.
Operator control (hardware)
3.3 7-segment display and LED display
SIMOTION D4x5
Manual, 04/2014 47