Page #24 background imageLoading...
Page #24 background image
Installing the Control System
2-12
SINUMERIK 802C base line
Start-Up
Cable lengths
The maximum cable length depends on the specifications of the encoder
power supply and on the transmission frequency.
To provide fault-free operation, make sure that the following values are not
exceeded when using preassembled interconnecting cables from SIEMENS:
Table 2–6 Maximum cable lengths depending on the encoder power supply
Supply Voltage Tolerance Current Consumption
Max. Cable
Length
5 V DC 4.75 V...5.25 V < 300 mA 25 m
5 V DC 4.75 V...5.25 V < 220 mA 35 m
Table 2–7 Maximum cable lengths depending on the transmission frequency
Encoder Type Frequency Max. Cable Length
1 MHz 10 mincremental
500 kHz 35 m
2.3.3 Configuration of the RS232 interface connection (X2)
Pin assignment of connector on the CNC side
RS232 interface
Connector designation: X2
RS232
Connector type: 9-pin sub-D plug connector
Table 2–8 Pin assignment of connector X2
Pin Name Type Pin Name Type
16DSRI
2RxD I 7RTS O
3TxD O 8CTS I
4DTR O 9
5M VO
1
5
6
9
Signal description:
RxD Receive Data
TxD Transmit Data
RTS Request to send
CTS Clear to send
DTR Data Terminal Ready
DSR Data Set Ready
M Ground
Signal level
RS232

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802C base line and is the answer not in the manual?

Siemens SINUMERIK 802C base line Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802C base line
CategoryController
LanguageEnglish

Related product manuals