Start-Up
SINUMERIK 802C base line
4-47
Start-Up
4.8 Series machine start–up
Functionality
The objective of series machine start–up is:
z
after commissioning, in order to bring another control system connected
to the same machine type with minimum effort to the condition as after
commissioning;
or
z
under service conditions (after replacing hardware components), to bring
a new control system to the initial state with minimum effort.
Precondition
To carry out commissioning, a PC/PG provided with a V24 interface for data
transfer from/to the control system is necessary.
In the PC/PG, the WINPCIN tool must be used.
Sequence of operations
1. Create the series machine start–up file (transfer from the control system
to the PC/PG).:
z
Make a V24 cable connection between the PC/PG (COM port) and the
SINUMERIK 802C base line (X2).
z
Select Binary format and the same baud rate both in the WinPCIN tool
and SINUMERIK 802C base line communication setting menu
z
Make the following settings in WINPCIN tool:
Receive data
Select the path where you want to save your data
Save
The PC/PG will set itself to “Receive” and will wait for data from the
control system.
z
Enter the password for protection level 2 in the control system.
z
Call the Services/RS232 setting menu.
z
Select the Start–up data line from the Services menu and press Start
data outp. to output the series machine start–up file.
2. Reading in the series machine start–up file into the SINUMERIK 802C
base line:
z
Enter the V24 interface settings as described under 1).
z
Press the Data In Start button in the Service menu. The control system is
thus ready to receive data.
z
Use the WINPCIN tool in the PC/PG to select the series start–up file from
the DATA_OUT menu and start data transfer.
z
The control system is brought to “RESET with rebooting” three times
during and at the end of data transfer. On completion of error–free data
transfer, the control system is completely configured and ready to
operate.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802C base line and is the answer not in the manual?

Siemens SINUMERIK 802C base line Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802C base line
CategoryController
LanguageEnglish

Related product manuals