Pin Signal name Type Meaning
5 P5 V, O Supply 5 V, max. 100 mA
6 OV_VS16 I Rotary switch position/value 16
7 OV_VS8 I Rotary switch position/value 8
8 OV_VS4 I Rotary switch position/value 4
9 OV_VS2 I Rotary switch position/value 2
10 OV_VS1 I Rotary switch position/value 1
Spindle override switch
Connector designation: X31
Connector type: 2 x 5-pin male connector, according to EN 60603-13 with coding
Max. cable length 1 m
Pin Signal name Type Meaning
1 - n.c.
2 - n.c.
3 M V Ground
4 - n.c.
5 P5 V, O Supply 5 V, max. 100 mA
6 OV_SP16 I Rotary switch position/value 16
7 OV_SP8 I Rotary switch position/value 8
8 OV_SP4 I Rotary switch position/value 4
9 OV_SP2 I Rotary switch position/value 2
10 OV_SP1 I Rotary switch position/value 1
5.1.5 Universal inputs and outputs X515, X516
Only switches (passive inputs) may be connected via the X515 and X516 connectors.
Connector designation: X515/X516
Connector type: Male connector, 20-pin
Max. cable length 2 m
Table 5-4 Assignment of connector X515
Pin Signal name Type Meaning
1 KT-IN1 I Customer key 1
2 KT-IN2 I Customer key 2
3 KT-IN3 I Customer key 3
4 KT-IN4 I Customer key 4
5 KT-IN5 I Customer key 5
6 KT-IN6 I Customer key 6
Connecting
5.1 interfaces
ONE MCP Part 1: MCP xxxx
36 Equipment Manual, 07/2020, A5E50324729B AA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK MCP-S Series and is the answer not in the manual?

Siemens SINUMERIK MCP-S Series Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK MCP-S Series
CategoryControl Panel
LanguageEnglish

Related product manuals