The switches S2-1 to S2-8 dene the default device name.
Up to 128 default device names are supported. If these default device names are used, there is
no need for initialization of the MCP.
Note
The default device names cannot be recongured using the STEP7 "Device initialization"
function for example.
If you are connecting the MCP to a SINUMERIK control as a PROFINET component, make sure that
this functionality is supported by the control concerned.
DCP mode:
No default device name is available in this mode. The device name must be set by means of an
initialization procedure and remains saved on the MCP. It is deleted again if the factory setting
is restored, e.g. using STEP 7.
Table 5-12 Settings of switch S2
1 2 3 4 5 6 7 8 9 10 Meaning
on on
on on on on on on on on DCP mode
on on on on on on on o Default device name: mcp-pn127
o on on on on on on o Default device name: mcp-pn126
on o on on on on on o Default device name: mcp-pn125
o o on on on on on o Default device name: mcp-pn124
on on o on on on on o Default device name: mcp-pn123
o on o on on on on o Default device name: mcp-pn122
on o o on on on on o Default device name: mcp-pn121
o o o on on on on o Default device name: mcp-pn120
on on on o on on on o Default device name: mcp-pn119
o on on o on on on o Default device name: mcp-pn118
on o on o on on on o Default device name: mcp-pn117
o o on o on on on o Default device name: mcp-pn116
on on o o on on on o Default device name: mcp-pn115
o on o o on on on o Default device name: mcp-pn114
on o o o on on on o Default device name: mcp-pn113
o o o o on on on o Default device name: mcp-pn112
x x x x x x x x "
on on on on o o o o Default device name: mcp-pn15
o on on on o o o o Default device name: mcp-pn14
on o on on o o o o Default device name: mcp-pn13
o o on on o o o o Default device name: mcp-pn12
on on o on o o o o Default device name: mcp-pn11
Connecting
5.1 interfaces
ONE MCP Part 1: MCP xxxx
42 Equipment Manual, 07/2020, A5E50324729B AA