- 31 -
3.4 Parameter setting method
Initial setting for the basic parameters
Refer to the controller’s (LEC series) operation manual for detail.
As the “basic parameter” is unique data of each actuator, if an actuator other than the “electric actuator /
slider type” is used, refer to the operation manual of each actuator and the controller’s (LEC series)
operation manual for the basic parameter.
Note1) Become effective after restarting the controller.
Note 2) Set the stroke setting value which has the additional distance. When inputting the product stroke,
the "stroke limit”alarm may be generated. (Code 1-052). (Stroke + 2mm as recommended)
Note 3) The initial input value is when the origin direction is “CCW”. When the origin direction set to “CW”,
input "2" to the “stroke(+)" and input “-(stroke)-2” to the “stroke(-)”.
Note 4) The origin offset is used for the “return to origin”. / See <Origin offset> on P.31.
Acceleration /
deceleration pattern
Max. speed of each
product
Step data input limit:
Max. speed of each product
Maximum acceleration /
deceleration
LEFS: 0.5 to product stroke
LEFB: 1 to product stroke
Origin direction: CCW:
-10000 + ”product stroke” to 9999
Origin direction: CW
-9999 to +10000 - ”product stroke”
Changeable parameter
1: Common + StepData, 2: Common
Select 1:
Enable
or 2:
Disable
when using a teaching box
Only the English characters and numbers are
changeable.
2021-05-2010:32
DW913599