-24-
No.PS##-OML0003-B
Setting of Function
■Function selection mode
In measurement mode, press the button for 2 seconds or longer to display [F 0]. Show the display of
function setting to be changed, [F ].
Press the
button for 2 seconds or longer in function selection mode to return to measurement mode.
∗: Some functions are not available depending on part number. All functions are displayed with [F ] and followed with function
description. If a function is not available for specified type, the function is displayed as [---].
■Default setting
At the time of shipment, the following settings are provided.
If the setting is acceptable, keep it for use.
To change setting, enter function selection mode.
•[F 0] Unit conversion function
See page 26
Unit specification Pressure range Default setting
ISE30A MPa
Nil or M
ZSE30A(F) kPa
ISE30A
P
ZSE30A(F)
psi
•[F 1] Parameter setting of OUT1 See page 27
Item Explanation Default setting
Output mode Selects hysteresis mode or window comparator mode. Hysteresis mode
Reversed output Selects reversed output. Normal output
Pressure setting Sets ON or OFF point of the switch output
ISE30A: 0.500 MPa
ZSE30A: -50.5 kPa
ZSE30AF: 50.0 kPa
Hysteresis Chattering can be prevented by setting hysteresis.
ISE30A: 0.050 MPa
ZSE30A: 5.0 kPa
ZSE30AF: 5.0 kPa
Display color Selects the display color.
ON: Green
OFF: Red