-47-
No.PS##-OML0003-B
Maintenance
How to reset the product for power cut or forcible de-energizing
The setting of the product is remained as that before power cut or de-energizing.
The output condition is also basically recovered to that before power cut or de-energizing, but may change
depending on the operating environment. Therefore, check the safety of whole facility before operating the
product.
If the facility is under accurate control, wait until it has warmed up. (Approximate 10 to 15 minutes)
Replacement of one-touch fitting
•The one-touch fitting has a cassette mechanism that can be replaced.
•Assembly should be performed after turning the power off, stopping the supplied fluid, exhausting the fluid
within the piping, and ensuring the release-to-atmosphere condition.
•The one-touch fitting is held by a one-touch clip inserted as shown in the figure below. Remove the one-touch
clip with a flathead screwdriver, and replace the one-touch fitting. To mount the one-touch fitting, insert the
one-touch fitting to the end, then insert the one-touch clip.
•Be careful not to damage the O-ring of the one-touch fitting.
•Supply pressure to the fitting slowly, and check if for leaks.