-13-
No.PS※※-OMM0007-H
Definition and terminology
Terms
Meaning
2
2-colour display
2 colours are used to indicate a value, which change according to the output
status.
7
7-segment display
When "8" is shown on the display. It is called 7-segment because 8 consists of
7 pieces of "- (segments)".
A
Analogue current output
Refer to "Analogue output (function)".
Analogue output function
Function to output the voltage or current in proportion to the pressure.
Analogue voltage output
Refer to "Analogue output (function)".
Auto preset
A function to automatically set up the pressure by having equipment hold and
release a workpiece via vacuum adsorption. This function is used in an
application where vacuum adsorption of a workpiece is confirmed by a
Pressure switch.
Auto shift
A function to correct the set value of the switch output in accordance with the
applied pressure in case the switch operation is unstable due to pulsation of
applied pressure. This function is used in applications such as vacuum
adsorption. The pressure when a signal is externally input is set as a reference
value with which the pressure that turns the switch on or off can be shifted.
B
Bottom value display
Indicates the minimum pressure reached up to that moment.
C
Chattering
The problem of the switch output turning ON and OFF repeatedly around the
set value at high frequency due to the effect of pulsation.
Chattering preventing function
A function to delay the response time of switch output in order to prevent
chattering.
Copy function
A function to copy a pressure setting value and function setting (excluding fine
adjustment of display value).
D
Digit (Min. setting unit)
Shows how precisely the pressure can be indicated or set by the digital
Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment
of 1 kPa, e.g., 1, 2, 3, …, 99, 100.
E
Error indication
With the self-diagnostic function of the Pressure switch, this indicates that there
is an error which could cause a switch failure.
F
Fine adjustment mode
Refer to "Fine adjustment of display value".
Fine adjustment of display value
A displayed pressure value can be adjusted within the range of ±5% R.D.
5% of the displayed value). It is used if a true pressure value is known or to
correct the difference of a displayed value of the measurement equipment
nearby which measures the same pressure.
F.S. (full span/full scale)
Abbreviation for full span and full scale; this means the maximum fluctuation
range of the Pressure switch rated value. For example, when the output voltage
is 1 to 5[V], the F.S. will be 5-1 = 4[V]. (Ref: 1%F.S. = 4 × 0.01 = 0.04[V])
Function selection mode
This is a mode in which each function is set up, and is a separate menu from
the pressure setup. If the setting needs to be changed, "F", each item can be
set up. The items to be set up are: display colour, operation mode, output type,
response time, display resolution, fine adjustment of indicated value, auto
preset, power-saving mode, and security code number.
H
Hysteresis
The difference between the pressure switch ON and OFF points, used to
prevent chattering
Hysteresis mode
Refer to "List of output modes" on page 30.