-61-
No.PS※※-OMM0007-H
Specification
■Specifications (Refer to page 63 for products with M8 (3 pin) connector)
ISE40A
(positive pressure)
Air, inert gases and incombustible gases
12 to 24 VDC ±10%, ripple (p-p) 10% or less (protected against reverse
connection)
NPN or PNP open collector output, 2 outputs
1 V or less (at 80 mA load current)
2.5 ms or less
(with anti-chatter function: 20, 100, 500, 1000 or 2000 ms)
Output Voltage
(rated pressure range)
Output current
(rated pressure range)
Max. load impedance: 300 (at power supply voltage of 12 VDC)
600 (at power supply voltage of 24 VDC)
Min. load impedance: 50
Non-voltage input (reed or solid state), Low level 0.4 V or less,
input time 5 ms or more
3 1/2digits, 7-segment, dual-colour display (red/green)
±2% F.S. ±1 digit (at ambient temperature 25±3 C)
LED is ON when output is ON OUT1, OUT2: Orange
Operation: -5 to 50 C, Storage: -10 to 60 C (no condensation or freezing)
Operation, Storage: 35 to 85% RH (no condensation)
1000 VAC, 1 minute between terminals and housing
50 M or more at 500 VDC between terminals and housing
Temperature characteristics
±2% F.S. (25 C reference)
Oil resistant vinyl cabtyre cable
5 cores 3.5, 2 m
Sectional area of conductor: 0.15 mm
2
(AWG26)
Outside diameter of insulator: 0.95 mm
1: If the applied pressure fluctuates around the set value, the hysteresis must be set to more than the fluctuation width. Otherwise,
chattering will occur.
2: If analogue voltage output is selected, the analogue current output cannot be selected.
3: If analogue current output is selected, the analogue voltage output cannot be selected.