No.PS※※-OMM0007-H
[F 0] Units selection function
Only the product with Units selection function can be set.
The displayed unit can be changed, and depends on the pressure range.
(kPa/MPa units are available when the product does not have the units selection function.)
<Operation>
Press the or button in function selection mode to display [F 0].
Press the button.
Move on to select the display unit.
Press the button to set. Return to function selection mode.
Setting of [F 0] Units selection function completed
Display unit and minimum setting unit
Unit
ZSE40AF
ZSE40A
ISE40A
MPa
0.001
0.001
0.001
kPa
0.1
0.1
1
kgf/cm
2
0.001
0.001
0.01
bar
0.001
0.001
0.01
psi
0.02
0.01
0.1
InHg
0.1
0.1
-
mmHg
1
1
-
Select the Display Unit
Press the or
button to select the display unit.