Troubleshooting
Self-diagnosis display
Five-digit display Cause and/or Corrective Actions
⢠You are using a battery pack that is not an
āInfoLITHIUMā battery pack.
c Use an āInfoLITHIUMā battery pack (p. 18, 239).
⢠Moisture condensation has occurred.
c Remove the cassette and leave your camcorder for at
least one hour to acclimatise (p. 244).
⢠The video heads are dirty.
c Clean the heads using the cleaning cassette (optional)
(p. 245).
ā¢A malfunction other than the above that you can service
has occurred.
c Remove the cassette and insert it again, then operate
your camcorder.
c Disconnect the mains lead of the AC power adaptor or
remove the battery pack. After reconnecting the power
supply, operate your camcorder.
ā¢A malfunction that you cannot service has occurred.
c Contact your Sony dealer or local authorised Sony
service facility and inform them of the 5-digit code
(example: E:61:10).
Your camcorder has a self-diagnosis display
function.
This function displays the current state of your
camcorder as a 5-digit code (a combination of a
letter and figures) on the screen. If a 5-digit code is
displayed, check the following list of codes. The
last two digits (indicated by ss) differ depending
on the state of your camcorder.
LCD screen, Viewfinder or
Display window
C:04:ss
C:21:ss
C:22:ss
C:31:ss
C:32:ss
E:20:ss
E:61:ss
E:62:ss
If you are unable to rectify the problem even if you try corrective actions a few times,
contact your Sony dealer or local authorised Sony service facility.
C:21:00
Self-diagnosis display
ā¢C:ss:ss
You can service your camcorder
yourself.
ā¢E:ss:ss
Contact your Sony dealer or local
authorised Sony service facility.