1-26
HDW-2000/M2000/M2000P/S2000/S2000P/M2100/M2100P, DVW-2000/2000P/M2000/M2000P
MSW-2000/A2000/A2000P/M2000/M2000P/M2000E/M2000EP/M2100/M2100P/M2100E/M2100EP
1-15. Settings and Adjustment when External Equipment is Connected
1-15-1.
Settings for Time Code (Recorder Only)
To set the TIME CODE, open the P1 page (TCG/TCR SETTING) on the function screen.
When Editing with an Editor (BVE-2000, etc.) Capable of the 1st Edit
When this unit is used by connecting to an editor, set as follows.
Button Model Item (Display) Setting
F1 HDW TCG SOURCE (TCG) INT
DVW/MSW TCG INT/EXT (TCG)
F2 HDW TCG PRESET/REGEN (PR/RGN) PRESET
DVW/MSW TCG PRESET/REGEN (TCG)
F3 HDW TCG RUN (RUN) FREE
DVW/MSW TCG RUN (RUN)
When Editing with Direct Machine-to-Machine (VTR to VTR)
n
The setup menu ITEM-610: REGEN CONTROL MODE setting data must be set to AS&IN.
Button Model Item (Display) Setting
F1 HDW TCG SOURCE (TCG) INT
DVW/MSW TCG INT/EXT (TCG)
F2 HDW TCG PRESET/REGEN (PR/RGN) PRESET
DVW/MSW TCG PRESET/REGEN (TCG)
F3 HDW TCG RUN (RUN) FREE
DVW/MSW TCG RUN (RUN) REC
1-15. Settings and Adjustment when External Equipment is Connected