19EN
4. INSTALLATION
4.3.3. CHECKS TO DEFINE THE VIRTUAL PERIMETERS:
1. Check that the maximum slope of the work area is less than or equal to 45% or 50% depending on
the model (see Par. 1.2 TECHNICAL DATA). For the de nition of virtual boundaries, please comply
with the rules shown in the following images:
a) if the slope is ≤ 20%, the virtual boundary can be positioned as shown;
b) if the slope is > 20% and ≤ 45% (50%) the installation must include the slope area observing the
distance indicated in the image;
c) if the slope is > 20% and the slope area is not part of the part of the garden to be cut, the
distance indicated in the image must be observed;
d) if the slope is > 45% (50%) the slope area must be excluded observing the distance indicated in
the image.
0÷20%
E
a
20÷45%
≥ 35cm
b
E
>20%
≥ 35cm
c
E
≥ 35cm
45%
>
d
E