Condition LEDs on
Charger
Cause Remedy
for about
1 second.
24 Specifications
24.1 STIHL HSA 60.0
Intended for household use.
–
Approved battery type: STIHL AK series
–
Weight without battery: 7.7 lbs. (3.5 kg)
24.2 Cutting Blades
–
Tooth spacing: 1.3 in. (34 mm)
–
Cutting length: 24 in. (600 mm)
–
Sharpening angle: 35°
24.3 STIHL AK Series Battery
Approved charger type: STIHL AL 101, AL 301
or AL 500 series.
–
Battery technology: Lithium-Ion
–
Voltage: 36 V
–
Rated capacity in Ah
1
: See rating plate
–
Stored energy in Wh
2
: See rating plate
–
Weight in kg: See rating plate
For a complete list of approximate charging
times, see www.stihl.com/charging-times.
For a complete list of approximate battery run‐
times, see www.stihl.com/battery-life.
24.4 STIHL AL 101
–
Mains voltage: 120 V
–
Rated current: 1.3 A
–
Frequency: 60 Hz
–
Charging current: 1.5 A
–
Rated power: 75 W
–
Insulation: Class II (Double Insulation)
24.5 Ambient Temperature Limits
WARNING
■ Extreme temperatures can damage the battery
and may also cause it to generate heat, rup‐
ture, leak, ignite or explode, resulting in severe
or fatal personal injury or property damage.
Never charge, use or store the battery outside
the ambient temperature limits specified
below.
►
Do not charge the battery below - 4 °F (-
20 °C) or above 122 °F (50 °C).
► Do not use the hedge trimmer, battery or
charger below ‑ 4 °F (- 20 °C) or above
122 °F (50 °C).
►
Do not store the hedge trimmer, battery or
charger below - 4 °F (- 20 °C) or above
158 °F (70 °C).
24.6 Ambient Temperature Recom‐
mendations
For optimum performance, observe the following
ambient temperature ranges for the hedge trim‐
mer, battery and charger:
–
Charging: 41 °F to 104 °F (5 °C to 40 °C)
–
Use: 14 °F to 104 °F (- 10 °C to 40 °C)
–
Storage: - 4 °F to 122 °F (- 20 °C to 50 °C)
Charging, using or storing the battery outside the
recommended ambient temperature ranges may
reduce performance.
If the battery became damp or wet during opera‐
tion, allow it to dry at least 48 hours at tempera‐
tures between 59 °F (15 °C) and 122 °F (50 °C)
and relative humidity below 70 % before charg‐
ing or storing. Higher humidity can extend the
drying time.
24.7 Symbols on the Hedge Trim‐
mer, Battery and Charger
Symbol Explanation
V Volt
1
Rated capacity calculated pursuant to IEC 61960. Usable energy available to the operator will be
less.
2
The battery is marked with its stored energy as provided by the cell manufacturer. Usable energy
available to the operator will be less.
English 24 Specifications
26 0458-019-8201-A