30
English
18 Troubleshooting
18.1 Correcting faults in the pressure washer
18 Troubleshooting
Fault Cause Remedy
The pressure washer does
not start although the
spray gun trigger is
squeezed.
The mains plug of the connecting cord or
extension cord is not plugged in.
Plug in mains plug of connecting cord or
extension cord.
The circuit breaker (fuse) or the overload cutout
has tripped. There is an electrical overload or a
fault in the circuit.
Look for cause of tripping and remedy it.
Insert circuit breaker (fuse) or overload
cutout.
Switch off other loads connected to the same
circuit.
The fuse rating of the socket is too low. Plug the connecting cord into a socket with
the correct fuse rating, @ 19.
The extension cord does not have the correct
cross-section.
Use an extension cord with an adequate
cross-section, @ 19.3
The extension cord is too long. Use an extension cord of the correct length,
@ 19.3
The electric motor is too warm. Allow the pressure washer to cool for
5 minutes.
Clean the nozzle.
The pressure washer does
not start when switched
on. The electric motor
hums.
The mains voltage is too low. Squeeze and hold the spray gun trigger and
switch on the pressure washer.
Switch off other loads connected to the same
circuit.
The extension cord does not have the correct
cross-section.
Use an extension cord with an adequate
cross-section, @ 19.3
The extension cord is too long. Use an extension cord of the correct length,
@ 19.3
The pressure washer
switches off while in
operation.
The plug of the connecting cord or extension
cord has been pulled out of the socket.
Plug in mains plug of connecting cord or
extension cord.
The circuit breaker (fuse) or the overload cutout
has tripped. There is an electrical overload or a
fault in the circuit.
Look for cause of tripping and remedy it.
Insert circuit breaker (fuse) or overload
cutout.
Switch off other loads connected to the same
circuit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stihl RE 120 and is the answer not in the manual?

Stihl RE 120 Specifications

General IconGeneral
Form factorUpright
Hose length8 m
Cable length5 m
Power sourceElectric
Product colorBlack, Orange
Pump materialAluminum
Detergent tank-
Maximum flow rate500 l/h
Minimum flow rate400 l/h
Sound power level81 dB
Vibration emission3.8 m/s²
Working pressure (max)140 bar
Working pressure (min)125 bar
Maximum water temperature40 °C
AC input voltage230 V
Power consumption (typical)- W