12
| Installation
Important
Damage to the bearings or other parts of the fan can
occur.
Do not place a duct bend directly before or after
the fan!
Ensure a smooth and constant air flow to the
device. Ensure a free exhaust. See .
Rectangular duct system: D = Hydraulic diameter
Round duct system: D = Nominal diameter
min.
2,5x Ø D
Ø D
8.1.1 DVC-P pressure tube
The following illustrations show the schematic installation of the pressure tubes.
Size
190–225
Size
315–710
A
B
A
Pressure tube
B Duct system
Controller input
-
Duct system
+
Atmosphere
8.2 Assembly/Disassembly impeller Internal rotor motor
If an external rotor motor is used, the motor and impeller can`t be seperated.
Important
Damage to the motor and impeller.
The ball bearing of the motor and the balanced impeller may be damaged by forceful impacts.
Attach the impeller and/or the shaft extension to the shaft or the rotor without forceful impacts.
Do not separate the impeller and the hub. They were balanced as one unit by Systemair.
Note:
The hub can be heated for easier assembly and disassembly, for example with a hot-air blower.
Precondition for assembly: the wedge is in the intended groove.
Tools: hexagon socket wrench and suitable tool for removal, torque wrench for the taper clamping bush.
| 005

Other manuals for SystemAir DVS series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SystemAir DVS series and is the answer not in the manual?

SystemAir DVS series Specifications

General IconGeneral
BrandSystemAir
ModelDVS series
CategoryFan
LanguageEnglish

Related product manuals