28 System Fault Finding T2004 Multi-Control Head System Manual
© Tait Electronics Limited May 2004
7 System Fault Finding
Problem
System will not power up, all heads appear dead.
Suggestion
Check radio has power connected and two micromatch connectors on
the interface board are not reversed.
Check pin 1 of interface board SK3 appears at J5 pin 1 at control heads.
SK3 pin 2 connects to J5 pin 2 etc.
Check for 13.8V at control heads.
Check Primary head is correctly fitted and turned on.
Problem
System will not power off.
Suggestion
Check all multi-drop wiring for shorts or faults.
Check only one Primary head is installed.
Problem
Head displays information but keypad, mic, etc. are dead.
Suggestion
This happens for ten seconds after power up on Secondary heads only.
If condition is permanent check data pair 2A/2B paying attention to
polarity.
Problem
Transmit/ Receive audio is very quiet.
Suggestion
Check for cable losses or faults. Max multi drop line length is 2km.