Warranted
Characteristics
Table B-9: Warranted Characteristics - Triggering System
Name
Description
Sensitivity•,
with
Coupling
DC
Source
Sensitivity
Internal
0.35
division
from
DC
to
5
MHz,
increasing
to
1.2
divi-
sion
at
60
MHz
External
b
40
mV
p-p
from
DC
to
5
MHz,
increasing
to
150
mV
p-p
at
60
MHz
Sensitivity
•,
with
Coupling
AC
Source
Sensitivity
Internal
0.35
division
from
50
Hz
to
5
MHz,
increasing
to
1.2
divi-
sion
at
60
MHz
External
h
40
mV
p-p
from
50
Hz
to
5
MHz,
increasing
to
150
mV
p-p
at
60
MHz
Sensitivity
•,
with
Coupling
NOISE
REJ
Source
Sensitivity
Internal
1.4
division
from
DC
to
5
MHz,
increasing
to
2.2
divi-
sion
at
60
MHz
External
b
160
mV
p-p
from
DC
to
5
MHz,
increasing
to
600
mV
p-p
at
60
MHz
Trigger
sensitivity
is
defined as the
minimum
peak-to-peak
sine-wave
signal
amplitude
required to
show
the test
signal
with
horizontal
jitter
of
less
than
3%
of
one
period
(p-p
viewed
over
two
seconds),with
trigger
LEVEL
control
set
at about midrange level, but not at control extremes.
External trigger
signal
from a
50
Q
source
driving a
50
Q
coaxial
cable
termi-
nated
in
50
Q at the input connector.
B
-18
Rev
12/92
Appendix
B:
Specifications

Table of Contents

Other manuals for Tektronix 2212

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2212 and is the answer not in the manual?

Tektronix 2212 Specifications

General IconGeneral
BrandTektronix
Model2212
CategoryTest Equipment
LanguageEnglish

Related product manuals