EasyManuals Logo
Home>Tektronix>Test Equipment>314

Tektronix 314 Manual

Tektronix 314
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
of
1
cycle
or
the
time
between
2
or
more
events
is
measu
red
(see
Frequency
Measurements).
A
portion
of
1
cycle,
or
a
full
cycle
is
usually
displayed
when
measuring
or
ob
serving
small
portions
of
a
wave
train
(such
as
risetime,
pulse
duration,
and
aberrations).
When
part
of
a
wave
train
or
waveform
that
occurs
later
than
the
sweep
trigger
are
to
be
examined,
the
X10
position
of
the
SWEEP
MAG
switch
can
be
used
to
expand
the
center
portion
of
the
dis
play.
The
effective
sweep
rate
for
the
expanded
portion
is
decreased
by
a
factor
of
10;
therefore,
timing
measurements
must
be
divided
by
10.
Portions
of
the
display
to
be
expand
ed
should
be
centered
with
the
POSITION
control
before
switching
to
the
X10
position.
SIGNAL
APPLICATION
TO
VERTICAL
INPUT
For
most
applications,
the
P6049B,
or
similar
probe,
should
be
used
as
an
interface
between
the
signal
source
and
the
oscilloscope
vertical
input.
The
probe
increases
the
input
resistance
of
the
oscilloscope
system
to
about
10
and
decreases
the
effective
capacitive
loading
to
about
13.5
pF.
The
higher
the
impedance
ratio
between
the
input
to
the
oscilloscope
system
and
the
signal
source,
the
less
the
cir
cuit
under
test
is
loaded,
and
the
more
accurate
the
measure
ment.
Because
of
circuit
loading
considerations,
all
measurements
should
be
made
at
low
impedance
points
in
the
circuit
being
tested.
NOTE
To
insure
that
measurements
are
accurate,
al
ways
compensate
the
probe
before
using.
To
compensate
the
probe,
touch
the
probe
tip
to
the
.5
V
CAL
OUT
connector
on
the
314
front
panel
and
adjust
the
compensation
for
the
best
front-corner
response
to
the
square
wave
signal
(set
VOLTS/DIV
switch
to
10m
and
TIME/DIV
switch
to
1
ms).
For
applications
in
which
the
source,
such
as
the
output
of
a
signal
generator,
is
a
coaxial
connector,
use
a
coaxial
cable
between
the
oscilloscope
and
the
signal
source.
In
this
application,
loading
is
not
a
problem;
however,
to
preserve
signal
fidelity,
the
cable
impedance
should
equal
the
source
impedance
and
the
cable
should
be
terminated
in
its
charac
teristic
impedance
at
the
oscilloscope
input.
Use
a
common-ground
return
between
the
signal
source
and
the
oscilloscope.
When
a
probe
is
used,
connect
the
shortest
possible
ground
lead
near
the
signal
source
to
avoid
a
long
signal
path
to
ground.
WA
RNING
I
If
the
314
is
powered
from
an
external
de
source
(not
connected
to
an
ac
power
source)
provide
314
Operators
13

Other manuals for Tektronix 314

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 314 and is the answer not in the manual?

Tektronix 314 Specifications

General IconGeneral
BrandTektronix
Model314
CategoryTest Equipment
LanguageEnglish

Related product manuals