Specifications
Table 7: Amplitude (cont.)
Characteristic Description
PV reference
page
AFG3251 / 3252 / 3251C /
3252C
50 mV
p-p
to5V
p-p
100 mV
p-p
to 10 V
p-p
(into open circuit load)
Accuracy
(See page 52,
Amplitude test.)
AFG3011 / 3011C ±(2% of setting +2 mV) (at 1 k Hz sine waveform amplitude > 10 mV
p-p
,
0V offset)
AFG3021B / 3021C / 3022B /
3022C / 3101 / 3101C / 3102 /
3102C / 3151C / 3152C/ 3251
/ 3251C / 3252 / 3252C
±(1% of setting +1 mV) (at 1 kHz sine waveform, amplitude > 10 mV
p-p
,
0 V offset)
Resolution 0.1 mV
p-p
,0.1mV
rms
, 1 mV, 0.1 dBm or 4 digits
Units
2
V
p-p
,V
rms
, dBm, and Volt (High level and Low level)
Output impedance 50 Ω
Isolation 42 V
pk
maximum to earth
1
AFG3251/ 3251C / 3252 / 3252C (frequency range: >200 MHz to 240 MHz): 50 mV
p-p
to 4 V
p-p
into 50 Ω,100mV
p-p
to 8 V
p-p
into open circuit load.
2
dBm is used only for sine waveform. V
rms
is not available for Arb and Noise waveforms.
3
AFG3151C/ 3152C (frequency range: >100 MHz to 150 MHz): 20 mV
p-p
to8V
p-p
into 50 Ω,40mV
p-p
to 16 V
p-p
into open circuit load.
Table 8: DC offset
Characteristic Description
PV reference
page
Range
AFG3011 / 3011C ±(10 V
pk
ac+dc into 50 Ω
±(20 V
pk
ac+dc into open circuit
AFG3021B / 3021C / 3022B /
3022C / 3051C / 3052C
±(5 V
pk
ac+dc into 50 Ω
±(10 V
pk
ac+dc into open-circuit load
AFG3101 / 3101C / 3102 /
3102C / 3151C / 3152C
±5 V DC into 50 Ω load
±10 V
pk
ac+dc into open-circuit load
AFG3251 / 3251C / 3252 /
3252C
±2.5 V DC into 50 Ω load
±5 V DC open circuit
Accuracy
1
±(1% of |setting| +5 mV + 0.5% of amplitude (V
p-p
)
±(2% of |setting| +10 mV + 1% of amplitude (V
p-p
)) (AFG3011C)
(See page 54,
DC Offset test.)
AFG3011 / 3011C
AFG3021B / 3021C / 3022B /
3022C / 3101 / 3101C / 3102
/ 3102C / 3151C / 3152C /
3251 / 3251C / 3252 / 3252C
±(1% of |setting| +5 mV + 0.5% of amplitude (V
p-p
))
Resolution 1 mV
Output impedance 50 Ω
1
AFG3011/3011C:Add1.0mVper°Cforoperationoutsidetherangeof20°Cto30°C.
AFG3021B / 3021C / 3022B / 3022C and AFG3101 / 31010C / 3102 / 3102C / 3151C / 3152C: Add 0.5 mV per °C for operation outside the range of 20 °C to
10 AFG3000C and AFG3000 Series Specifications and Performance Verification
30 °C.
AFG3251 / 3251C / 3252 / 3252C: Add 2.0 mV per °C for operation outside the range of 20 °C to 30 °C.