EasyManuals Logo
Home>Tektronix>Inverter>AFG3011C

Tektronix AFG3011C Technical Reference

Tektronix AFG3011C
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
Performance verification
AFG325x /
325xC Spectrum analyzer Measurement
50.00 MHz 10 MHz
300 MHz
20 MHz
600 MHz
20 kHz
20 kHz
MHz
MHz
dBc
dBc
< -41 dBc
100.00 MHz 10 MHz
300 MHz
20 MHz
600 MHz
20 kHz
20 kHz
MHz
MHz
dBc
dBc
< -35 dBc
200.00 MHz 10 MHz
300 MHz
20 MHz
600 MHz
20 kHz
20 kHz
MHz
MHz
dBc
dBc
< -29 dBc
240.00 MHz 10 MHz
300 MHz
20 MHz
600 MHz
20 kHz
20 kHz
MHz
MHz
dBc
dBc
< -28 dBc
Rise-Fall time test
This test
verifies the pulse rise time of the arbitrary function generator.
1. Connect the arbitrary function generator to the oscilloscope as shown in the
followi
ng figure.
Figure 14: Ri se-Fall time tests
2. Set up the arbitrary function generator using the following steps:
Select menu Setting Operation
Function
Square Square (front)
Frequency
2.00 MHz: AFG3011 /
3011C
10.00 MHz: AFG302xB
/ 302xC / 305xC / 310x /
310xC / 3151C / 3152C
/ 325x / 325xC
Frequency/Period (front)
Amplitude Units Vpp
TopMenu > Amplitude/Level Menu >
-more- > U nits > Vpp
Amplitude 1.0 Vpp
Amplitude/High (front)
AFG3000C and AFG3000 Series Specifications and Performance Verification 67

Table of Contents

Other manuals for Tektronix AFG3011C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix AFG3011C and is the answer not in the manual?

Tektronix AFG3011C Specifications

General IconGeneral
BrandTektronix
ModelAFG3011C
CategoryInverter
LanguageEnglish

Related product manuals