Commands Listed in Alphabetical Order
Syntax
TRIGger:A:BUS
{I2C|SPI|CAN|RS232}
TRIGger:A:BUS?
Arguments
I2C specifies the Inter-IC bus.
SPI specifie
s the Serial Peripheral Interface bus.
CAN specifies the Controller Area Network bus.
TRIGger:A:BUS:B<x>:CAN:CONDition
Sets or returns the CAN trigger condition for bus <x>, where x is the bus number.
Conditions
Require
s a DPO2AUTO application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:CAN:CO NDition
{SOF|FRAMEtype|IDentifier |DATA|IDANDDATA|EOF|ACKMISS}
TRIGger:A:BUS:B<x>:CAN:CO NDition?
Arguments
SOF enables triggering on the start of frame.
FRAMEtype enables triggering on the type of frame.
IDentifier enables triggering on a matching identifier.
DATA enables triggering on matching data.
IDANDDATA enables triggering on a matching identifier an d matching data.
EOF enables triggering on the end of frame.
ACKMISS enables triggering on a missing acknowledge.
Examples
TRIGGER:A:BUS:B1:CAN:COND ITION? might return :TRIGGER:A:BUS:B1:
CAN:CONDITION EOF indicating an end of file condition.
TRIGGER:A:BUS:B1:CAN:COND ITION DATA enables triggering on matching
CAN data.
2-296 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual