Installation
Operating Considerations
MSO2000B and DPO2000B Series Oscillos copes
Power Supply Input Voltage: 100 V to 240 V ± 10%
Power Supply Input Power Frequency:
50/60 Hz at 100 V to 240 V
400 Hz at 115 V
Power Consumption: 80 W m aximum
Weight: 3.6 kg (7 lbs 14 oz), stand-alone oscilloscope
Height, including the feet but not the handle:
175 mm (6.885 inch)
Width: 377 mm (14.85 inch)
DPO2000B series
Depth: from the feet to the front of the knobs: 134 mm (5.3 inch)
Depth: fr
om the feet to the front of the front cover: 139 mm (5.47 inch)
Clearan
ce: 50 mm (2 inch)
Input V
oltage (between the signal and reference):
300 V
RMS
CAT II
Installation Category II - for measurements performed
on circ
uits directly connected to the low-voltage
installation
Tempe
rature:
Operating: 0 °C to +50 °C
Nonoperating: -20 °C to +60 °C
MSO2000B series
Humidity:
Operating: High: 40 °C to 50 °C, 10% to 60% RH
Operating: Low: 0 °C to 40 °C, 10% to 90% RH
Non-operating: High: 40 °C to 60 °C, 5% to 60% RH
Non-operating: Low: 0 °C to 40 °C, 5% to 90% RH
Altitude:
Operating: 3,000 m (9,842 ft)
Nonoperating Altitude: 12,000 m (39,370 ft)
MSO2000B and DPO2000B Series Oscilloscopes User Manual 5