REMOTE CONTROL
61
Trigger Commands
The trigger commands generate and configure software triggers.
This power supply supports the following two trigger functions.
• TRANsient
Specifies the current and voltage settings in advance and uses the
trigger to set them. Please refer to VOLT:TRIG, CURR:TRIG on
page 56 and 62 for details.
• OUTPut
Specifies the output on/ off settings in advance and uses the trigger
to set them. Please refer to OUTP:TRIG on page 62 for details.
RIGger:TRANsient[:IMMediate]..................................... 61
TRIGger:TRANsient:SOURce ........................................... 61
TRIGger:OUTPut[:IMMediate] ......................................... 62
TRIGger:OUTPut:SOURce ................................................ 62
TRIGger:TRANsient[:IMMediate]
Description
Generates a software trigger for the transient
trigger system.
Syntax TRIGger:TRANsient[:IMMediate]
TRIGger:TRANsient:SOURce
Description
Sets or queries the trigger source for the transient
system.
Syntax
Query Syntax
TRIGger:TRANsient:SOURce {BUS | IMMediate}
TRIGger:TRANsient:SOURce?
Parameter/Return
BUS
Internal software trigger. Waits for the
*TRG (or IEEE 488.1 “get” group
execute trigger) command to start the
trigger.
IMMediate
Starts the trigger immediately.
(default)
Set
Set
Query
All manuals and user guides at all-guides.com