Command Descriptions
TDS Family Oscilloscope Programmer Manual
2–67
CH<x>:SCAle <NR3>
CH<x>:SCAle?
CH
<x> :
SCAle
?
<Space>
<NR3>
<NR3> is the gain, in volts per division. The range is 100 mV per division to
1 mV per division when using a 1x probe.
CH4:SCALE 100E-03
sets the channel 4 gain to 100 mV per division.
CH2:SCALE?
might return 1.00E+0, indicating that the current V per division setting of
channel 2 is 1 V per division.
CH<x>:VOLts
Sets or queries the vertical gain of the specified channel. This command is
identical to the CH<x>:SCAle command and is included for compatibility
purposes. Only CH<x>:SCAle is returned in response to a CH<x>? query.
Vertical
CH1:SCAle
CH<x>:VOLts <NR3>
CH<x>:VOLts?
CH
<x> :
VOLts
?
<Space> <NR3>
CH4:VOLTS 100E-03
sets the channel 4 gain to 100 mV per division.
CH2:VOLTS?
might return 1.00E+0, indicating that the current V per division setting of
channel 2 is 1 V per division.
Syntax
Arguments
Examples
Group
Related Commands
Syntax
Examples