Performance Verication
3. Connect the osc
illoscope channel under test to the DC voltage source as
shown in the following gure:
4. For each vertical scale (volts/division) setting in the following table, perfor m
the following steps:
a. Set the DC voltage source output level to the positive voltage listed a nd
then record the mean m ea surement as V
pos
.
b. Reverse the polarity of the DC voltage source and record the mean
measurement as V
neg
.
c. Calculate V
diff
=V
pos
-V
neg
and compare V
diff
to the accuracy limits in
the following table:
Vertical Scale
(volts/div) setting
DC voltage
source output levels Accuracy limits f or V
diff
5 mV/div
+17.5 mV, -17.5 mV 33.6 mV to 36.4 mV
200 mV/div
+700 mV, -700 mV 1.358 V to 1.442 V
2V/div
+7.00 V, -7.00 V 13.58 V to 14.42 V
5. Set DC voltage source output level to 0V.
6. Disconnect the test setup.
7. Repeat steps 1 through 3 for all input channels.
30 TDS2000C and TDS1000C-EDU Series Oscilloscope Service Manual

Table of Contents

Other manuals for Tektronix TDS2002C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS2002C and is the answer not in the manual?

Tektronix TDS2002C Specifications

General IconGeneral
BrandTektronix
ModelTDS2002C
CategoryOscilloscope
LanguageEnglish

Related product manuals