11
[Left Side]
19
17. Remote master volume adjustment terminals
Removable terminal block (5 pins).
Release voltage: 24 V DC or less.
The unit’s master volume control can be remotely
operated by connecting an external resistor to
these terminals.
(See p. 16, "Remote master volume adjustment
terminal connection.")
Note
Use a 10 kΩ variable resistor (B curve) for the
external resistor.
If the resistor’s resistance value is small, the unit’s
sound level will be reduced, and if the resistance
value is large, the sound level will be increased.
18. DIP switch
Used to select the input sensitivities of Inputs 1
and 2 and the output impedance of the speaker
terminals.
• Switch1
Selects Input 1 sensitivity.
UP: LINE
DOWN: MIC
• Switch2
Selects Input 2 sensitivity.
UP: LINE
DOWN: MIC
• Switch3
Not used. Leave this switch in its default position
(UP).
• Switch4
Switches the speaker output between low and
high impedance.
UP: Low-impedance
DOWN: High-impedance
Note
All switches of the DIP switch are factory-preset
to the UP position.
19. Fan
Exhaust fan.
Note
Avoid blocking the fan, as this could result in unit
failure.

Other manuals for Toa A-5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toa A-5000 Series and is the answer not in the manual?

Toa A-5000 Series Specifications

General IconGeneral
BrandToa
ModelA-5000 Series
CategoryAmplifier
LanguageEnglish

Related product manuals