12
Warning! Switch o the machine and unplug from the electrical supply before performing any cleaning operations.
1. Move the Transport / Working mode control knob to BOTTOM (Transport)
position to move the brushes o of the oor (Fig-viii).
2. Unplug the machine and wrap the supplu cord aroung the hooks on the
handle.
3. Pull out the dirty water tank and wash it completely.
4. To prevent possible clogging of the solution lines in the solution tank, empty
any unused solution from the tank.lter, drain cleaning liquid and keep the
fresh water tank clean.
5. Remove the brushes by pushing the brush shaft out (Fig-ix).
6. Wash the brushes either by dipping in a bucket/sink or in running water
(Fig-x).
7. Turn the machine on its side and wipe clean the rubberized drum and
machine body with a damp cloth (Fig-xi).
8. Re-install the brushes after washing. It is easier to push the brush shaft from
the right hand side (identied by the electrical cable).
9. Store the machine in a dry indoor area only.
Warning! Before undertaking any maintenance operations or adjustments, switch o the machine
and unplug from the electrical supply.
3
2
1
(ix)
(x)
(xi)
Cleaning the Machine
Maintenance
To get the maximum life of the machine, do the following:
• Supply Cord
Regularly inspect sheath, plug and cord anchorage for damage or loose connection. Replaced if
damaged.
• Brushes
Wash the brushes regularly. Make sure that the machine is in Transport Mode when not in use.
Store additional brushes in a vertical position to avoid bending the bristles. Check for permanent
bending of bristles in a particular direction. This may occur if the machine is operated for several days
without removing the brushes, which is not recommended. If this occurs, reverse the brush so that the bent
bristles are straightened.
• Wiper Blade
If the wiper blade wears out, the water collection performance will decrease. It should be replaced by an
authorized service agent.
• Solution Feed Filter (Pump)
The lter should be periodically cleaned. Use pressurized air/water for cleaning.
• Nozzle Maintenance (Pump)
If the spray nozzle is blocked, slide the nozzle cover o and remove the nozzle. Clean it with clean water and
use a pin to unclog, then reinstall.