3.Rotatetheengineignitionkeytothe“START”
positionandquicklyreleaseittothe“ON”position.
Thiswakesupthereceiver(Figure13).
Note:Ifthekeywasleftintheonpositionforan
extendedtime,movethekeytotheoffposition
beforeproceedingtothestartingprocedure.
4.Ontheremote,usethefollowingsequencetostart
theengine:
Note:Usingthissequencepreventstheremote
fromaccidentallystartingtheengine.
PresstheSTARTbutton.
Then,presstherotateleftbutton.
Then,presstherotaterightbutton.
Then,pressandholdtheSTARTbuttonuntil
theenginestarts.
Important:Donotengagestarterformore
than10secondsatatime.Ifenginefailsto
startallow30secondcool-downperiodbetween
attempts.Failuretofollowtheseinstructions
canburnoutstartermotor.
Note:IftheSTARTbuttonispressedinadvertently
withoutcompletingthestartingsequence,thechute
directionbuttonswillnotfunction.Wait5seconds
beforepressingthechutedirectionbuttons.
5.Aftertheenginestarts,movethechokecontrolto
theoffposition.Iftheenginestallsorhesitates,
movethechokebacktotheONpositionforafew
seconds,thensettheenginespeedtothedesired
setting.Repeatthisasrequired.
StoppingtheEngine
1.Decreasetheenginespeedmidwaybetweenthe
slowandfastpositions.
2.Lettheengineidlefor20seconds.
3.PresstheSTOPbuttonontheremote.
4.Ifleavingthemachine,rotatethekeytotheOFF
positionandremoveitfromtheengine(
Figure13).
Important:Thelightsonthecontrolmodule
willstayonandthechutecanberotatedfor2.5
hoursafterthekeyisturnedoff.
Figure13
1.Ignitionswitch3.Hourmeter
2.Chokecontrol
ControllerTimeOut
Theblowerisequippedwithatime-outfeatureforthe
controlmodule.Thetime-outfeatureisactivatedafter
2.5hoursofcontinuousremotetransmitterinactivity.
Wheninthetime-outmodetheenginewillnotrun
(orwillquitrunning)andtheremotetransmitter
willnotcontrolanyfunction.
Towakecontrollerintime-outmode,turnthekey
switchtotheOFFpositionandthenturnthekey
switchtothestartpositionmomentarily(enginewill
turnover).
Toavoidcontrollertime-outduringoperation,use
theremotetransmittertorotatethechuteorchange
theenginespeedatleastevery2.5hours.
AdjustingtheNozzleDirection
Thedirectionofthenozzleopeningcanbechanged
fromrighttoleftbypressingtheappropriatebuttonon
theremotecontrol(Figure14).