E6582051
- 39 -
6.5.2. fa06 (Communication command1) (VF-AS3)
bit Function 0 1 Note
0
Preset speed switching
1
0000: Preset speed operation
OFF(*1)
0001-1111: Setting of preset speed
operation frequencies (1-15)
Preset speed operation is
disabled or preset speed
operation frequencies (1-15) are
set by specifying bits for preset
speed operation frequencies 1-4.
1
Preset speed switching
2
2
Preset speed switching
3
3
Preset speed switching
4
4 V/f switching 1 (*2) V/f 1 V/f 2
V/f 1:
pt
= setting value,
vl, vlv, vb, thra
V/f 2:
pt
= 0,
f170
,
f171
,
f172
,
f182
5 PID control Normal operation PID off -
6
Acc/Dec switching 1
(*3)
AD mode 1 AD mode 2
AD mode 1:
acc
,
dec
AD mode 2:
f500
,
f501
7 DC braking OFF
Forced DC
braking
-
8 Jog run OFF Jog run -
9 Forward/Reverse Forward run Reverse run -
10 Run/stop Stop Run -
11 Coast stop command Standby Cost stop -
12 Emergency stop OFF Emergency stop Always enable, "E" trip
13 Fault reset OFF Reset No data is returned from the drive
14 Frequency priority OFF Enabled
Enabled regardless of the setting
of
fmod
15 Command priority OFF Enabled
Enabled regardless of the setting
of
cmod
(*1): When 12(
sr0
) is set to
fmod
, preset speed operation frequency 0 is selected.
(*2): The V/f switching ORs with Bit 10 of
fa23
.
(*3): The Acc/Dec switching ORs with Bit 8 of
fa23