E6582051
- 40 -
6.5.3.
fa23
(Communication command 2) (VF-S15/MB1)
bit Function 0 1 Note
0 (Reserved) - - -
1
Electric power quantity
reset
OFF Reset
Electric power quantity (
fe76
,
fe77
) reset
2 (Reserved) - - -
3 (Reserved) - - -
4 (Reserved) - - -
5 (Reserved) - - -
6 (Reserved) - - -
7
Maximum deceleration
forced stop
Normal Enabled -
8
Acceleration/decele-
ration selection 1
00: Acceleration/deceleration 1
01: Acceleration/deceleration 2
10: Acceleration/deceleration 3
Select acceleration/deceleration
1-4 by combination of two bits.
AD1:
acc
,
dec
AD2:
f500
,
f501
AD3:
f510
,
f511
9
Acceleration/decele-
ration selection 2
10 (Reserved) - - -
11 (Reserved) - - -
12 OC stall level switch OC stall 1 OC stall 2
OC stall 1:
f601
OC stall 2:
f185
13 (Reserved) - - -
14 (Reserved) - - -
15 (Reserved) - - -
Note: Set 0 to reserved bit.

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-AS3
CategoryInverter
LanguageEnglish

Related product manuals