50 51
M aintenanc e
M aintenanc e
Water Filter (Bowl Unit)
W ater F il ter ( B ow l U nit)
(Approximately once every 6 months)
W ater F il ter ( B ow l U nit)
(Approximately once every 6 months)
( C ontinu ed )
Remove the shutoff valve cover, and then
close the shutoff valve.
The water supply stops.
Press "Wand CLEAN" button.
Opens the wand cover.
(Release the pressure from the water supply pipe.)
Switch the breaker on the distribution board to OFF.
Loosen the cap of the water lter to remove
the water lter.
Use the opening/closing tool (accessory).
Remove the water lter from the cap
and clean it with a toothbrush or similar
instrument.
Do not use detergent.
Do not apply excessive force to the water filter.
(May cause deformation.)
1
C A U T I ON
Do not remove the water lter
w h il e th e s h u tof f v al v e is open.
(Otherwise, water may leak out.)
2
3
4
5
Toothbrush,
etc.
Attach the water lter to the cap.
Install the cap of the water lter to the
original position and tighten it with the
opening/closing tool.
Open the shutoff valve, and then install
the shutoff valve cover.
Check that there are no leaks in the shutoff valve
or plumbing connections.
Switch the breaker on the distribution
board to ON.
The "Power" LED lights up.
6
7
8
9
Opening/closing tool
Water lter
Cap
Opening /
closing tool
(accessory)
or flat-head
screwdriver
Shutoff valve
cover
H ol d th e pipe w ith h and s
w h il e tig h tening th e c ap.
H ol d th e pipe w ith h and s
w h il e l oos ening th e c ap.