38 39
Maintenance
Descaling mode
Water fi lter drain valve (Perform once every 6 months)
<If you think the water pressure has weakened>
1
Close the shutoff valve.
•
The water supply stops.
CAUTION
Do not remove the water fi lter drain
valve while the shutoff valve is open.
(Otherwise, water may leak out)
2
Extend the wand.
•
Operate with the buttons on the back side
of the remote control.
(1) Press [MENU].
(2)
Use
to select [CLEANING].
Press [ENTER].
(3)
Use
to select [WAND
CLEANING MODE ON/OFF].
Press [ENTER] to extend the
wand.
Press [ENTER] again to retract
the wand.
(Release the pressure from the
water supply pipe.)
3
Unplug the power plug.
(Page 15)
Switch the breaker on the
distribution board to OFF.
(Concealed power connection type)
4
Remove the cover and water
fi lter drain valve.
•
Loosen with a fl at-head screwdriver and
then pull.
Cover
Water filter
drain valve
5
Clean with a tool such as a
toothbrush.
•
Also, remove any dust from inside the hole
of the water fi lter drain valve.
6
Reinstall the water fi lter drain
valve and cover.
•
Insert the water fi lter drain valve and tighten
it securely with a fl at-head screwdriver.
Cover
7
Insert the power plug.
(Page 15)
Switch the breaker on the
distribution board to ON.
(Concealed power connection type)
8
Open the shutoff valve.
(Page 15)
Descaling mode <If you think the water pressure has weakened>
<When [POWER] LED (orange) and [ENERGY SAVER] LED (orange) fl ash> (Continued)
9
Remove the funnel and put cap and cover back on.
Funnel
Cap
Cover
10
Perform descaling. (2nd time)
Press [ENTER].
DESCALING MODE
FILL IN THE
DESCALING AGENT (2/2)
PUSH
[ENTER]
1/1
Descaling will be performed
( for about 60 minutes)
•
Water will be sprayed from around the
wand and mist nozzle at about 20-minute
intervals
After about 60 minutes, descaling agent
will be drained to the toilet
After draining, you will hear a long beep
sound, and the LEDs on product main
body stop fl ashing
<Descaling complete>
DESCALING MODE
DESCALING IN
PROGRESS
PLEASE
WAIT FOR
60 MINUTES
Returns to default display in about 30 seconds.
Attention!
●
If the spray is still weak afte performing
Descaling mode
please clean
Water fi lter drain valve .
●
If the symptom does not improve after conducting
Descaling mode
and cleaing
Water fi lter drain valve
or if
the [POWER] (orange) and [ENERGY SAVER] (orange) LEDs start to fl ash, please perform
Descaling mode again.
Water fi lter drain valve
Maintenance
Attention!
●
Please wipe off any spilt agent with soft
wetted cloth
(Failure to do so may cause discoloration)