Model Number Descriptions
Unit Model Number
Digit 1, 2, 3 Unit Model
ACR = Air-Cooled Screw Chiller
Digit 4 Series
C = Series C
Digit 5, 6, 7 Nominal Tonnage
150 = 150 Tons
165 = 165 Tons
180 = 180 Tons
200 = 200 Tons
225 = 225 Tons
250 = 250 Tons
275 = 275 Tons
300 = 300 Tons
330 = 330 Tons
375 = 375 Tons
380 = 380 Tons
440 = 440 Tons
450 = 450 Tons
500 = 500 Tons
550 = 550 Tons
Digit 8 Compressor Type
4 = Mixed screw types
5 = GP4 Screw with Variable Volume Ratio
Digit 9— Unit Voltage
A = 200/60/3
B = 230/60/3
C = 380/60/3
D = 400/60/3
E = 460/60/3
F = 575/60/3
Digit 10 Manufacturing Location
U = Trane Commercial Systems,
Pueblo, CO USA
G = Trane Commercial Systems,
Grand Rapics, MI USA
Digits 11, 12 Design Sequence
** = Factory assigned
Digit 13 Unit Sound Package
R = InvisiSound™ Standard with Noise Reduction
Request
Q = InvisiSound™ Superior with Noise Reduction
Request
E = InvisiSound™ Ultimate
Digit 14 Agency Listing
C = No Agency Listing
E = ETL Listed/Certified to CSA/Conforms to UL
Digit 15 Pressure Vessel Code
U = ASME Pressure Vessel Code
C = CRN or Canadian Equivalent Pressure Vessel
Code
Digit 16 Factory Charge
E = Refrigerant Charge R-513A
F = Nitrogen Charge, R-513A Field Supplied
Digit 17 Auxiliary Items
X = No Auxiliary Items
Digit 18 Evaporator Application
N = Standard Cooling
P = Low Temp Process Cooling
C = Ice Making
Digit 19, 20 Evaporator Type
C1 = CHIL 1-pass
C2 = CHIL 2-pass
C3 = CHIL 3-pass
Digit 21 Water Connection
X = Grooved Pipe
A = Grooved Pipe + Flange
Digit 22 Flow Switch
C = Flow Switch Set Point 15 cm/sec
D = Flow Switch Set Point 25 cm/sec
F = Flow Switch Set Point 35 cm/sec
H = Flow Switch Set Point 45 cm/sec
L = Flow Switch Set Point 60 cm/sec
Digit 23 Insulation
N = Factory Insulation All Cold Parts 0.75”
H = Evaporator-only Insulation for High Humidity/
Low Evap Temp 1.25”
Digit 24 Unit Application
X = Standard Ambient
L = Low Ambient
E = Extreme Low Ambient
H = High Ambient
W = Wide Ambient
Digit 25 Condenser Length
A = 4V Condenser Coil Modules
B = 5V Condenser Coil Modules
C = 6V Condenser Coil Modules
D = 7V Condenser Coil Modules
E = 8V Condenser Coil Modules
F = 9V Condenser Coil Modules
H = 11V Condenser Coil Modules
Digit 26 Condenser Fin Options
M = Aluminum Microchannel
C = Coated Microchannel
P = Premium Coated Microchannel
Digit 27 Fan Type
E = EC Condenser Fan Motors
Digit 28 Compressor Starter
V = Variable Frequency Drive (1 compressor/
circuit)
Digit 29 Incoming Unit Power Line
Connection
1 = Single Point Power
2 = Dual Point Unit Power Connection
3 = Single Point Power including 115V
Digit 30 Power Line Connection Type
T = Terminal Block
C = Circuit Breaker
H = Circuit Breaker with High Fault Rated Control
Panel
Digit 31 Short Circuit Current Rating
A = Default Short Circuit Amp Rating
B = High Short Circuit Amp Rating
Digit 32 Electrical Accessories
N = 20A 115V Convenience Outlet

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane Ascend ACR C Series and is the answer not in the manual?

Trane Ascend ACR C Series Specifications

General IconGeneral
BrandTrane
ModelAscend ACR C Series
CategoryChiller
LanguageEnglish

Related product manuals