6 AFDH-SVN03H-EN
Model Number Descriptions
Unit Model Number
For service purposes, Trane Model
AFDH Air-Cooled drive upgrade
packages are assigned a multiple
character alphanumeric model
number that precisely identifies each
unit.
An explanation of the identification
code that appears on the unit
nameplate is shown below. Use of
the service model number will
enable the owner/operator, installing
contractors, and service technicians
to define the operation, components,
and options for any specific unit.
Refer to the model number printed
on the nameplate when ordering
replacement parts or requesting
service.
Example model number:
AFDH0312FD0A0M21C20D00A
1A00
Digit 1, 2, 3 Unit Function
A = Adaptive
F = Frequency
D = Drive
Digit 4 Development
Sequence
H = Development Sequence
(Air Cooled)
Digit 5, 6, 7, 8 Unit
Performance RLA
0312= 312 Rated Load Amps
Digit 9 Chiller Voltage
F = 460 Volts 60 Hz 3 Phase
G = 480 Volts 60 Hz 3 Phase
H = 575 Volts 60 Hz 3 Phase
J = 600 Volts 60 Hz 3 Phase
R = 380 Volts 50 Hz 3 Phase
T = 400 Volts 50 Hz 3 Phase
Digit 10, 11 Design Sequence
D0, E0= D-Frame Redesign (new model
number)
Digit 12 Short Circuit Rating
A = 65K Short Circuit Rating
B = 100K Short Circuit Rating
C = 35K Short Circuit Rating
Digit 13,14 Maximum RLA
575 V/600 V
2B = 192 Maximum RLA 60 Hz
0L = 242 Maximum RLA 60 Hz
0M = 290 Maximum RLA 60 Hz
0N = 344 Maximum RLA 60 Hz
0P = 400 Maximum RLA 60 Hz
460 V/480 V
0C = 302 Maximum RLA 60 Hz
0D = 361 Maximum RLA 60 Hz
0E = 443 Maximum RLA 60 Hz
1A = 535 Maximum RLA 60 Hz
380 V/400 V
0W = 315 Maximum RLA 50 Hz
0X = 395 Maximum RLA 50 Hz
0Y = 480 Maximum RLA 50 Hz
0Z = 588 Maximum RLA 50 Hz
Digit 15 Chiller Control Type
1 = UCP2 Controls
2 = CH531/Tracer® AdaptiView™
Controls
Digit 16 Agency Listing
0 = No Listing
1 = UL Listing (includes Canada
and California)
Digit 17 AFD Enclosure Type
C = Retrofit Enclosure—NEMA 1
Digit 18 Mounting Type
1 = Unit Mounted
2 = Remote
Digit 19 AFD To Motor
Transition
0 = No Motor Transition
A = 6 in. Sheetmetal Transition
B = 18 in. Sheetmetal Transition
C = 12 in. Sheetmetal Transition
Digit 20— Frame Size
D = D-Frame
Digit 21 Future Use (not used)
0 = Not Used
Digit 22 Future Use (not used)
0 = Not Used
Digit 23 Harmonic
Attenuation
0 = No Harmonic Attenuation
1 = 414 Max RLA Line Reactor
2 = 643 Max RLA Line Reactor
3 = 500 Max RLA Line Reactor
4 = 1200 Max RLA Line Reactor
A = 320 Amp Harmonic Filter
B = 403 Amp Harmonic Filter
C = 482 Amp Harmonic Filter
D = 636 Amp Harmonic Filter
Digit 24— Lug Size
1 = Standard Lugs
A = Optional Lugs
Digit 25— Jumper Size
0 = No Jumper Bars Required
A = Bar Kit 1
B = Bar Kit 2
C = Bar Kit 3
D = Bar Kit 4
E = All Bars Included
Digit 26, 27 Design Specials
00