EasyManuals Logo

Trane TAM4A0A18S11ED User Manual

Trane TAM4A0A18S11ED
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
17
Section 7. Setting the Unit - Vertical Installation
7.1 Considerations
Provide a minimum height of 14 inches for proper
unrestricted airflow below the unit. Allow a minimum
of 21 inches clearance in front of the air handler to
permit maintenance and removal of filter.
Position unit on suitable foundation. If a manu-
facturer approved accessory is not used, a frame
strong enough to support the total weight of the
unit, accessories, and duct work must be provided.
Isolate unit from the foundation using a suitable
isolating material.
Typical Closet Installation
7.2 Upflow Installations
Typical TASB Installation
Airflow
AirflowAirflow
TASB Installation
1. Install the TASB plenum stand with integrated
sound baffle using the TASB instructions.
Note: Kit is used for open air applications.
TASB175SB for use with 17.5” cabinets
TASB215SB for use with 21.5” cabinets
TASB235SB for use with 23.5: cabinets
MITISRKIT1620 - Side return kit with 16”x20” filter
Contact your distributor for more information.
Plenum Installation
1. Assemble the plenum using the plenum’s
Installer Guide.
Airflow
On units with sheet metal returns: Return plenum
must be flanged. Sheet metal drill point screws
must be 1/2” in length or shorter.
Typical Plenum Installation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane TAM4A0A18S11ED and is the answer not in the manual?

Trane TAM4A0A18S11ED Specifications

General IconGeneral
BrandTrane
ModelTAM4A0A18S11ED
CategoryAir Handlers
LanguageEnglish

Related product manuals