Note: When in “SET HEAD OFF” mode, the function “SET GAP AUTO”
doesn’t work even the printer head is opened and closed, but it can work when
power on the printer.
Example
The example below is operated in DOS environment via the parallel port connection to
setup the label size, gap distance and sensor sensitivity.
C:\>COPY CON LPT1<ENTER>
SIZE 4,2.5<ENTER>
GAP 0.12,0<ENTER>
SET GAP 1<ENTER>
<CTRL><Z><ENTER>
C:\>
Note: <ENTER> stands for keyboard “ENTER” key. In the above example, please
press “ENTER” key instead of typing <ENTER> in the above example. <CTRL>
stands for keyboard “Ctrl” key.
Troubleshooting:
Press the FEED key to test. Does printer stop at the same position on each label without
the error light blinking? If not, adjust the setting to a larger number. When adjusting
this setting, begin from 0 and then on to higher values incrementally.